â—Ź Full voltage input
â—Ź Miniaturization
â—Ź Protection Short circuit / overload / overvoltage
â—Ź 100% full load burn-in test
Output adjustment range ---------------± 5% ( Rated output voltage )
Overload ------------------- 105% to 200% ( rated load ) , since the resumption of
Overvoltage protection ------------------- 115% ~ 135% ( rated output voltage )
Short circuit protection ------------------- self-recovery
Work environment ------------------ -10 ° ~ 50 °; 20% ~ 90% RH ( non-condensing )
Tips: Power 100% full, but will consume part of the power wiring, it is recommended to use the power of 80% to 85 % of the products .
1. Notice
( 1 ) The input voltage should be connected within the specified operating range
( 2 ) Prohibited the use in high temperature environments , the power should have good heat dissipation space and the environment.
( 3 ) Prohibited the power supply mounted on flammable ( such as wood products , flammable plastic, etc.) , to stay away from petrol stations or prohibit fireworks places.
2 . Installation method
( 1 ) In strict accordance with the position indicated by wiring the power supply terminals, wiring should be strong, determined not to reverse the input and output lines (input \"L (AC) N\" then the mains ; ), Output : \"- V\" then load the negative, output \"+ V\" connected load positive)